60W Triple Output Switching Power SupplyT-60 series

60W Triple Output Switching Power Supply Features:
Universal AC input / Full range
Protections: Short circuit/Over load/Over voltage
Cooling by free air convection
LED indicator for power on
Fixed switching frequency at 50KHz
SPECIFICATION:
MODEL

T-60A

T-60B

T-60C

OUTPUT DC VOLTAGE 5V 12V -5V 5V 24V -12V 5V 15V -15V
RATED CURRENT 5A 2.5A 0.5A 5A 2.5A 0.5A 5A 2A 0.5A
CURRENT RANGE 0.5 ~ 7A 0.2 ~ 3.5A 0 ~ 1A 0.5 ~ 7A 0.2 ~ 3.5A 0 ~ 1A 0.5 ~ 7A 0.2 ~ 3A 0 ~ 1A
RATED POWER 57.5W 61W 62.5W
RIPPLE & NOISE (max.) Note.2 100 mVp-p 100 mVp-p 100 mVp-p 100 mVp-p 100 mVp-p 100 mVp-p 100 mVp-p 100 mVp-p 100 mVp-p
VOLTAGE ADJ. RANGE CH1: 4.75 ~ 5.5V CH1: 4.75 ~ 5.5V CH1: 4.75 ~ 5.5V
VOLTAGE TOLERANCE Note.3 ±2.0% ±6.0% ±6.0% ±2.0% ±6.0% ±6.0% ±2.0% ±6.0% ±6.0%
LINE REGULATION ±0.5% ±1.0% ±0.5% ±0.5% ±1.0% ±0.5% ±0.5% ±1.0% ±0.5%
LOAD REGULATION ±1.0% ±4.0% ±1.0% ±1.0% ±4.0% ±1.0% ±1.0% ±4.0% ±1.0%
SETUP, RISE, HOLD TIME 300ms, 50ms, 80ms/230VAC 800ms, 50ms,10ms/115VAC at full load
INPUT VOLTAGE RANGE 85 ~ 264VAC 120 ~ 370VDC
FREQUENCY RANGE 47 ~ 63Hz
EFFICIENCY (Typ.) 72% 72% 72%
AC CURRENT 2A/115VAC 1A/230VAC
INRUSH CURRENT (max.) COLD START 20A/115VAC 40A/230VAC
LEAKAGE CURRENT <3.5mA / 240VAC
PROTECTION OVERLOAD 105 ~ 150% rated output power.
Protection type: Hiccup mode, recovers automatically after fault condition is removed.
OVER VOLTAGE CH1: 5.75 ~ 6.75V
Protection type: Hiccup mode, recovers automatically after fault condition is removed.
ENVIRONMENT WORKING TEMP. -10 ~ +60ºC (Refer to output load derating curve)
WORKING HUMIDITY 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY -20 ~ +85ºC, 10 ~ 95% RH
TEMP. COEFFICIENT ±0.03%/ºC (0 ~ 50ºC)
VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & EMC (Note.4) SAFETY STANDARDS Design refer to UL1012, UL60950, TUV EN60950 
WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
HARMONIC CURRENT Compliance to EN61000-3-2,-3
EMS IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, Light industry level, criteria A
OTHERS MTBF 281.1K hrs min. MIL-HDBK-217F (25ºC)
DIMENSION 159*97*38mm (L*W*H)
PACKING 0.494Kg; 30pcs/16.41Kg/0.0250CMB
NOTE 1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature.
2.Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3.Tolerance: includes set up tolerance, line regulation and load regulation.
4.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.