SPECIFICATION:
| MODEL |
SCN-800-12 |
SCN-800-15 |
SCN-800-24 |
SCN-800-48 |
| OUTPUT |
DC VOLTAGE |
12V |
15V |
24V |
48V |
| RATED CURRENT |
66A |
54A |
33A |
16.6A |
| CURRENT RANGE |
0 ~ 66A |
0 ~ 54A |
0 ~ 33A |
0 ~ 16.6A |
| RATED POWER |
800W |
800W |
800W |
800W |
| RIPPLE & NOISE (max.) Note.2 |
150mVp-p |
150mVp-p |
240mVp-p |
480mVp-p |
| VOLTAGE TOLERANCE Note.3 |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
| LINE REGULATION |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
| LOAD REGULATION |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
| SETUP, RISE, HOLD TIME |
800ms, 50ms, 16ms at full load |
| INPUT |
VOLTAGE RANGE |
90 ~ 130VAC / 180~260VAC selected by switch, 260~370VDC |
| FREQUENCY RANGE |
47 ~ 63Hz |
| EFFICIENCY (Typ.) |
77% |
80% |
81% |
82% |
| AC CURRENT |
11A / 115VAC 7.0A / 230VAC |
| INRUSH CURRENT (max.) |
60A / 230VAC |
| LEAKAGE CURRENT |
3.5mA / 240VAC |
| PROTECTION |
OVERLOAD |
110~135% rated output power |
| Protection type: Current limiting, delay shut down o/p voltage, re-power on to recover. |
| OVER VOLTAGE |
110~135% follow to output set up point |
| Protection type: Shut down o/p voltage, re-power on to recover. |
| OVER TEMPERATURE |
>100ºC / measure by heat sink, near transformer |
| Protection type: Shut down o/p voltage, re-power on to recover |
| ENVIRONMENT |
WORKING TEMP.,HUMIDITY |
-10 ~ +65ºC (Refer to output load derating curve), 20 ~ 90% RH |
| STORAGE TEMP., HUMIDITY |
-20 ~ +85ºC, 10 ~ 95% RH |
| TEMP. COEFFICIENT |
±0.04%/ºC (0 ~ 50ºC) |
| VIBRATION |
10 ~ 200Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes |
| SAFETY & EMC |
SAFETY STANDARDS |
Design refer to UL1950, CSA22.2, IEC60950 |
| EMI CONDUCTION & RADIATION |
Design refer to FCC part 15 class A |
| WITHSTAND VOLTAGE |
I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
| ISOLATION RESISTANCE |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC |
| OTHERS |
MTBF |
120khrs min. MIL-HDBK-217F (25ºC) |
| DIMENSION |
291*132*68mm (L*W*H) |
| PACKING |
2.3kg; 8pcs/ 24kg/ CARTON |
| NOTE |
1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature. 2.Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3.Tolerance: includes set up tolerance, line regulation and load regulation. 4.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. |