SPECIFICATION:
| MODEL |
S-40-5 |
S-40-12 |
S-40-15 |
S-40-24 |
| OUTPUT |
DC VOLTAGE |
5V |
12V |
15V |
24V |
| RATED CURRENT |
8A |
3.5A |
2.8A |
1.8A |
| CURRENT RANGE |
0 ~ 8A |
0 ~ 3.5A |
0 ~ 2.8A |
0 ~ 1.8A |
| RATED POWER |
40W |
42W |
42W |
43W |
| RIPPLE & NOISE (max.) Note.2 |
75mVp-p |
100mVp-p |
100mVp-p |
100mVp-p |
| VOLTAGE ADJ. RANGE |
4.75 ~ 5.5V |
10.8 ~ 13.2V |
13.5 ~ 16.5V |
21.6 ~ 26.4V |
| VOLTAGE TOLERANCE Note.3 |
±2.0% |
±1.0% |
±1.0% |
±1.0% |
| LINE REGULATION |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
| LOAD REGULATION |
±1.0% |
±0.5% |
±0.5% |
±0.5% |
| SETUP, RISE TIME |
300ms, 50ms/230VAC 800ms, 50ms/115VAC at full load |
| HOLD TIME(Typ.) |
70ms/230VAC 15ms/115VAC at full load |
| INPUT |
VOLTAGE RANGE |
85 ~ 264VAC 120 ~ 370VDC |
| FREQUENCY RANGE |
47 ~ 63Hz |
| EFFICIENCY (Typ.) |
72%/115VAC |
76%/115VAC |
76%/115VAC |
78%/115VAC |
| AC CURRENT |
1.2A/115VAC 0.6A/230VAC |
| INRUSH CURRENT (max.) |
COLD START 25A/115VAC 50A/230VAC |
| LEAKAGE CURRENT |
<1mA / 240VAC |
| PROTECTION |
OVERLOAD |
105 ~ 150% rated output power |
| Protection type: Hiccup mode, recovers automatically after fault condition is removed. |
| OVER VOLTAGE |
5.75 ~ 6.75V |
13.8 ~ 16.2V |
17.25 ~ 20.25V |
27.6 ~ 32.4V |
| Protection type: Hiccup mode, recovers automatically after fault condition is removed |
| ENVIRONMENT |
WORKING TEMP. |
-10 ~ +60ºC (Refer to output load derating curve) |
| WORKING HUMIDITY |
20 ~ 90% RH non-condensing |
| STORAGE TEMP., HUMIDITY |
-20 ~ +85ºC, 10 ~ 95% RH |
| TEMP. COEFFICIENT |
±0.03%/ºC (0 ~ 50ºC) |
| VIBRATION |
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes |
| SAFETY & EMC (Note.4) |
SAFETY STANDARDS |
Design refer to UL1012, UL1950, TUV EN60950 |
| WITHSTAND VOLTAGE |
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
| ISOLATION RESISTANCE |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC |
| EMI CONDUCTION & RADIATION |
Compliance to EN55022 (CISPR22) Class B |
| HARMONIC CURRENT |
Compliance to EN61000-3-2,-3 |
| EMS IMMUNITY |
Compliance to EN61000-4-2,3,4,5; ENV50204, EN55024, Light industry level, criteria A |
| OTHERS |
MTBF |
314.1K hrs min. MIL-HDBK-217F (25ºC) |
| DIMENSION |
129*98*38mm (L*W*H) |
| PACKING |
0.412Kg; 45pcs/20.43Kg/0.0326CMB |
| NOTE |
1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature. 2.Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3.Tolerance: includes set up tolerance, line regulation and load regulation. 4.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. |