SPECIFICATION:
| MODEL |
S-320-5 |
S-320-7.5 |
S-320-12 |
S-320-13.5 |
S-320-15 |
S-320-24 |
S-320-27 |
S-320-48 |
| OUTPUT |
DC VOLTAGE |
5V |
7.5V |
12V |
13.5V |
15V |
24V |
27V |
48V |
| RATED CURRENT |
50A |
36A |
25A |
22A |
20A |
12.5A |
11A |
6.5A |
| CURRENT RANGE |
0 ~ 50A |
0 ~ 36A |
0 ~ 25A |
0 ~ 22A |
0 ~ 20A |
0 ~ 12.5A |
0 ~ 11A |
0 ~ 6.5A |
| RATED POWER |
250W |
270W |
300W |
297W |
300W |
300W |
297W |
312W |
| RIPPLE & NOISE (max.) Note.2 |
150mVp-p |
150mVp-p |
150mVp-p |
150mVp-p |
150mVp-p |
150mVp-p |
200mVp-p |
240mVp-p |
| VOLTAGE ADJ. RANGE |
4.5 ~ 5.7V |
6 ~ 9V |
10 ~ 13.2V |
12 ~ 15V |
13.5 ~ 18V |
20 ~ 26.4V |
26 ~ 32V |
41 ~ 56V |
| VOLTAGE TOLERANCE Note.3 |
±2.0% |
±2.0% |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
| LINE REGULATION |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
| LOAD REGULATION |
±1.0% |
±1.0% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
| SETUP, RISE, HOLD TIME |
2000ms, 20ms, 24ms at full load |
| INPUT |
VOLTAGE RANGE |
88 ~ 132VAC / 176 ~ 264VAC by switch 248 ~ 370VDC |
| FREQUENCY RANGE |
47 ~ 63Hz |
| EFFICIENCY (Typ.) |
77% |
80% |
82% |
83% |
84% |
86% |
86% |
87% |
| AC CURRENT |
6A/115VAC 3.5A/230VAC |
| INRUSH CURRENT (max.) |
18A/115VAC 36A/230VAC |
| LEAKAGE CURRENT |
<3.5mA / 240VAC |
| PROTECTION |
OVERLOAD |
105 ~ 135% rated output power |
| Protection type: Hiccup mode, recovers automatically after fault condition is removed. |
| OVER VOLTAGE |
5.75 ~ 6.75V |
9.4 ~ 10.9V |
13.8 ~ 16.2V |
15.5 ~ 18.2V |
18 ~ 21V |
27.6 ~ 32.4V |
33.7 ~ 39.2V |
57.6 ~ 67.2V |
| Protection type: Hiccup mode, recovers automatically after fault condition is removed. |
| FAN CONTROL O.T.P. |
RTH1 ≧65ºC FAN ON, ≦55ºC FAN OFF, ≧70ºC (5 ~ 15V) |
| RTH1 ≧70ºC FAN ON, ≦65ºC FAN OFF, ≧80ºC (24 ~ 48V) |
| Protection type: Hiccup mode, recovers automatically after fault condition is removed. |
| ENVIRONMENT |
WORKING TEMP. |
-10 ~ +60ºC (Refer to output load derating curve) |
| WORKING HUMIDITY |
20 ~ 90% RH non-condensing |
| STORAGE TEMP., HUMIDITY |
-20 ~ +85ºC, 10 ~ 95% RH |
| TEMP. COEFFICIENT |
±0.03%/ºC (0 ~ 50ºC) |
| VIBRATION |
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes |
| SAFETY & EMC |
SAFETY STANDARDS |
Design refer to UL1950 |
| WITHSTAND VOLTAGE |
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
| ISOLATION RESISTANCE |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC |
| OTHERS |
MTBF |
188.7K hrs min. MIL-HDBK-217F (25ºC) |
| DIMENSION |
215*115*50mm (L*W*H) |
| PACKING |
0.939Kg; 12pcs/13.74Kg/0.0263CMB |
| NOTE |
1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature. 2.Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3.Tolerance: includes set up tolerance, line regulation and load regulation. |