SPECIFICATION:
| MODEL |
S-240-5 |
S-240-7.5 |
S-240-12 |
S-240-15 |
S-240-24 |
S-240-30 |
S-240-48 |
| OUTPUT |
DC VOLTAGE |
5V |
7.5V |
12V |
15V |
24V |
30V |
48V |
| RATED CURRENT |
40A |
30A |
18A |
15A |
10A |
8A |
5A |
| CURRENT RANGE |
0 ~ 40A |
0 ~ 30A |
0 ~ 18A |
0 ~ 15A |
0 ~ 10A |
0 ~ 8A |
0 ~ 5A |
| RATED POWER |
200W |
225W |
216W |
225W |
240W |
240W |
240W |
| RIPPLE & NOISE (max.) Note.2 |
150mVp-p |
200mVp-p |
150mVp-p |
150mVp-p |
180mVp-p |
180mVp-p |
240mVp-p |
| VOLTAGE ADJ. RANGE |
4.5 ~ 5.8V |
6 ~ 9V |
10 ~ 14V |
12 ~ 18V |
20 ~ 28V |
27 ~ 33V |
41 ~ 56V |
| VOLTAGE TOLERANCE Note.3 |
±2.0% |
±2.0% |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
| LINE REGULATION |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±1.0% |
| LOAD REGULATION |
±1.0% |
±1.0% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±1.0% |
| SETUP, RISE, HOLD TIME |
1000ms, 20ms, 36ms at full load |
| INPUT |
VOLTAGE RANGE |
88 ~ 132VAC / 176 ~ 264VAC Auto switch 248 ~ 370VDC |
| FREQUENCY RANGE |
47 ~ 63Hz |
| EFFICIENCY (Typ.) |
78% |
80% |
82% |
83% |
84% |
85% |
87% |
| AC CURRENT |
5A/115VAC 2.5A/230VAC |
| INRUSH CURRENT (max.) |
15A/115VAC 30A/230VAC |
| LEAKAGE CURRENT |
<2mA / 240VAC |
| PROTECTION |
OVERLOAD |
105 ~ 135% rated output power |
| Protection type: Hiccup mode, recovers automatically after fault condition is removed. |
| OVER VOLTAGE |
6 ~ 7V |
9.4 ~ 10.9V |
14.4 ~ 16.8V |
18.5 ~ 21.5V |
31.2 ~ 36V |
34.5 ~ 40.5V |
57.6 ~ 67.2V |
| Protection type: Hiccup mode, recovers automatically after fault condition is removed. |
| FUNCTION |
FAN CONTROL,O.T.P. |
RT1≧40ºC FAN ON, ≦35ºC FAN OFF, ≧70ºC output shut down |
| ENVIRONMENT |
WORKING TEMP. |
-10 ~ +60ºC (Refer to output load derating curve) |
| WORKING HUMIDITY |
20 ~ 90% RH non-condensing |
| STORAGE TEMP., HUMIDITY |
-20 ~ +85ºC, 10 ~ 95% RH |
| TEMP. COEFFICIENT |
±0.03%/ºC (0 ~ 50ºC) |
| VIBRATION |
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes |
| SAFETY & EMC (Note.4) |
SAFETY STANDARDS |
Design refer to UL1950, TUV EN60950 (7.5V Design refer to TUV EN60950-1) |
| WITHSTAND VOLTAGE |
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
| ISOLATION RESISTANCE |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC |
| EMI CONDUCTION & RADIATION |
Compliance to EN55022 (CISPR22) Class B |
| HARMONIC CURRENT |
Compliance to EN61000-3-2,-3 |
| EMS IMMUNITY |
Compliance to EN61000-4-2,3,4,5,6,8,11;ENV50204,Light industry level,criteria A |
| OTHERS |
MTBF |
179.3K hrs min. MIL-HDBK-217F (25ºC) |
| DIMENSION |
190*93*65mm (L*W*H) |
| PACKING |
0.956Kgs/pcs, 12pcs/12.73Kgs/0.0263CMB |
| NOTE |
1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature. 2.Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3.Tolerance: includes set up tolerance, line regulation and load regulation. 4.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. |