SPECIFICATION:
| MODEL |
S-100F-5 |
S-100F-7.5 |
S-100F-12 |
S-100F-15 |
S-100F-24 |
S-100F-48 |
| OUTPUT |
DC VOLTAGE |
5V |
7.5V |
12V |
15V |
24V |
48V |
| RATED CURRENT |
20A |
13.5A |
8.5A |
6.7A |
4.5A |
2.2A |
| CURRENT RANGE |
0 ~ 20A |
0 ~ 13.5A |
0 ~ 8.5A |
0 ~ 6.7A |
0 ~ 4.5A |
0 ~ 2.2A |
| RATED POWER |
100W |
101W |
102W |
100.5W |
108W |
105.6W |
| RIPPLE & NOISE (max.) Note.2 |
100mVp-p |
125mVp-p |
125mVp-p |
125mVp-p |
150mVp-p |
150mVp-p |
| VOLTAGE ADJ. RANGE |
4.5 ~ 5.5V |
6.75 ~ 8.25V |
10.8 ~ 13.2V |
13.5 ~ 16.5V |
21.6 ~ 26.4V |
43.2 ~ 52.8V |
| VOLTAGE TOLERANCE Note.3 |
±2.0% |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
| LINE REGULATION |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
| LOAD REGULATION |
±1.0% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
| SETUP, RISE, HOLD TIME |
1000ms, 30ms at full load |
| HOLD TIME(TYP.) |
20ms at full load |
| INPUT |
VOLTAGE RANGE |
88 ~ 132VAC/176 ~ 264VAC selected by jumper or switch 248 ~ 370VDC |
| FREQUENCY RANGE |
47 ~ 63Hz |
| EFFICIENCY (Typ.) |
76% |
78% |
80% |
81% |
83% |
84% |
| AC CURRENT |
3.15/115VAC 1.5A/230VAC |
| INRUSH CURRENT (max.) |
COLD START 20A/115VAC 40A/230VAC |
| LEAKAGE CURRENT |
<1mA / 240VAC |
| PROTECTION |
OVERLOAD |
105 ~ 150% rated output power |
| Protection type: Hiccup mode, recovers automatically after fault condition is removed. |
| OVER VOLTAGE |
5.75 ~ 6.75V |
8.63 ~ 10.13V |
13.8 ~ 16.2V |
17.25 ~ 20.25V |
27.6 ~ 32.4V |
55.2 ~ 64.8V |
| Protection type: Hiccup mode, recovers automatically after fault condition is removed. |
| ENVIRONMENT |
WORKING TEMP. |
-10 ~ +60ºC (Refer to output load derating curve) |
| WORKING HUMIDITY |
20 ~ 90% RH non-condensing |
| STORAGE TEMP., HUMIDITY |
-20 ~ +85ºC, 10 ~ 95% RH |
| TEMP. COEFFICIENT |
±0.03%/ºC (0 ~ 50ºC) |
| VIBRATION |
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes |
| SAFETY & EMC (Note.4) |
SAFETY STANDARDS |
Design refer to UL1012, UL1950, TUV EN60950 |
| WITHSTAND VOLTAGE |
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
| ISOLATION RESISTANCE |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC |
| EMI CONDUCTION & RADIATION |
Compliance to EN55022 (CISPR22) Class B |
| HARMONIC CURRENT |
Compliance to EN61000-3-2,-3 |
| EMS IMMUNITY |
Compliance to EN61000-4-2,3,4,5;6,8,11; ENV50204, EN55024, Light industry level, criteria A |
| OTHERS |
MTBF |
314.9K hrs min. MIL-HDBK-217F (25ºC) |
| DIMENSION |
199*98*38mm (L*W*H) |
| PACKING |
0.605Kg; 30pcs/20.05Kg/0.0250CMB |
| NOTE |
1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature. 2.Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3.Tolerance: includes set up tolerance, line regulation and load regulation. 4.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. |