100W Single Output Switching Power SupplyS-100F series

100W Single Output Switching Power Supply Features:
AC input range selectable by switch
Protections: Short circuit/Over load/Over voltage
Cooling by free air convection
100% full load burn-in test
Fixed switching frequency at 83KHz
SPECIFICATION:
MODEL

S-100F-5

S-100F-7.5

S-100F-12

S-100F-15

S-100F-24

S-100F-48

OUTPUT DC VOLTAGE 5V 7.5V 12V 15V 24V 48V
RATED CURRENT 20A 13.5A 8.5A 6.7A 4.5A 2.2A
CURRENT RANGE 0 ~ 20A 0 ~ 13.5A 0 ~ 8.5A 0 ~ 6.7A 0 ~ 4.5A 0 ~ 2.2A
RATED POWER 100W 101W 102W 100.5W 108W 105.6W
RIPPLE & NOISE (max.) Note.2 100mVp-p 125mVp-p 125mVp-p 125mVp-p 150mVp-p 150mVp-p
VOLTAGE ADJ. RANGE 4.5 ~ 5.5V 6.75 ~ 8.25V 10.8 ~ 13.2V 13.5 ~ 16.5V 21.6 ~ 26.4V 43.2 ~ 52.8V
VOLTAGE TOLERANCE Note.3 ±2.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
LINE REGULATION ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
LOAD REGULATION ±1.0% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
SETUP, RISE, HOLD TIME 1000ms, 30ms at full load
HOLD TIME(TYP.) 20ms at full load
INPUT VOLTAGE RANGE 88 ~ 132VAC/176 ~ 264VAC selected by jumper or switch           248 ~ 370VDC
FREQUENCY RANGE 47 ~ 63Hz
EFFICIENCY (Typ.) 76% 78% 80% 81% 83% 84%
AC CURRENT 3.15/115VAC     1.5A/230VAC
INRUSH CURRENT (max.) COLD START 20A/115VAC 40A/230VAC
LEAKAGE CURRENT <1mA / 240VAC
PROTECTION OVERLOAD 105 ~ 150% rated output power
Protection type: Hiccup mode, recovers automatically after fault condition is removed.
OVER VOLTAGE 5.75 ~ 6.75V 8.63 ~ 10.13V 13.8 ~ 16.2V 17.25 ~ 20.25V 27.6 ~ 32.4V 55.2 ~ 64.8V
Protection type: Hiccup mode, recovers automatically after fault condition is removed.
ENVIRONMENT WORKING TEMP. -10 ~ +60ºC (Refer to output load derating curve)
WORKING HUMIDITY 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY -20 ~ +85ºC, 10 ~ 95% RH
TEMP. COEFFICIENT ±0.03%/ºC (0 ~ 50ºC)
VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & EMC (Note.4) SAFETY STANDARDS Design refer to UL1012, UL1950, TUV EN60950 
WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
HARMONIC CURRENT Compliance to EN61000-3-2,-3
EMS IMMUNITY Compliance to EN61000-4-2,3,4,5;6,8,11; ENV50204, EN55024, Light industry level, criteria A
OTHERS MTBF 314.9K hrs min. MIL-HDBK-217F (25ºC)
DIMENSION 199*98*38mm (L*W*H)
PACKING 0.605Kg; 30pcs/20.05Kg/0.0250CMB
NOTE 1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature.
2.Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3.Tolerance: includes set up tolerance, line regulation and load regulation.
4.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.