100W Single Output Switching Power SupplyS-100 series

100W Single Output Switching Power Supply Features:
AC input range selectable by switch
Protections: Short circuit/Over load
Cooling by free air convection
100% full load burn-in test
Fixed switching frequency at 25KHz
Low cost
High reliability
SPECIFICATION:
MODEL

S-100-5

S-100-7.5

S-100-10

S-100-12

S-100-15

S-100-18

S-100-24

S-100-27

S-100-48

OUTPUT DC VOLTAGE 5V 7.5V 10V 12V 15V 18V 24V 27V 48V
RATED CURRENT 20A 13.6A 10A 8.5A 6.7A 5.6A 4.5A 3.7A 2A
CURRENT RANGE 0 ~ 20A 0 ~ 13.6A 0 ~ 10A 0 ~ 8.5A 0 ~ 6.7A 0 ~ 5.6A 0 ~ 4.5A 0 ~ 3.7A 0 ~ 2A
RATED POWER 100W 102W 100W 102W 100.5W 100.8W 108W 99.9W 96W
RIPPLE & NOISE (max.) Note.2 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p
VOLTAGE ADJ. RANGE 4.75 ~ 5.5V 6.75 ~ 8.25V 9 ~ 11V 10.8 ~ 13.2V 13.5 ~ 16.5V 16.2 ~ 19.8V 21.6 ~ 26.4V 24.4 ~ 29.7V 43.2 ~ 52.8V
VOLTAGE TOLERANCE Note.3 ±2.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
LINE REGULATION ±0.5% ±0.5% ±0.3% ±0.3% ±0.3% ±0.3% ±0.2% ±0.2% ±0.2%
LOAD REGULATION ±0.5% ±0.5% ±0.3% ±0.3% ±0.3% ±0.3% ±0.2% ±0.2% ±0.2%
SETUP, RISE, HOLD TIME 200ms, 80ms, 20ms at full load
INPUT VOLTAGE RANGE 85 ~ 132VAC/180 ~ 264VAC selected by switch       255 ~ 370VDC
FREQUENCY RANGE 47 ~ 63Hz
EFFICIENCY (Typ.) 78% 80% 80% 81% 81% 82% 84% 84% 84%
AC CURRENT 2.4A/115VAC 1.2A/230VAC
INRUSH CURRENT (max.) COLD START 30A/115VAC 60A/230VAC
LEAKAGE CURRENT <1mA / 240VAC
PROTECTION OVERLOAD 105 ~ 150% rated output power (150 ~ 200% rated output power for S-100-7.5 only)
Protection type: Shut down o/p voltage, re-power on to recover.
ENVIRONMENT WORKING TEMP. -10 ~ +60ºC (Refer to output load derating curve)
WORKING HUMIDITY 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY -20 ~ +85ºC, 10 ~ 95% RH
TEMP. COEFFICIENT ±0.03%/ºC (0 ~ 50ºC)
VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & EMC SAFETY STANDARDS Design refer to UL1012
WITHSTAND VOLTAGE I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
EMI CONDUCTION & RADIATION Design refer to FCC Part15 J Conduction Class B
OTHERS MTBF 322.4K hrs min. MIL-HDBK-217F (25ºC)
DIMENSION 199*98*38mm (L*W*H)
PACKING 0.578Kg; 30pcs/19.24Kg/0.0250CMB
NOTE 1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature.
2.Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3.Tolerance: includes set up tolerance, line regulation and load regulation.