SPECIFICATION:
| MODEL |
PT-65A |
PT-65B |
PT-65C |
PT-65D |
| OUTPUT |
OUTPUT NUMBER |
CH1 |
CH2 |
CH3 |
CH1 |
CH2 |
CH3 |
CH1 |
CH2 |
CH3 |
CH1 |
CH2 |
CH3 |
| DC VOLTAGE |
5V |
12V |
-5V |
5V |
12V |
-12V |
5V |
15V |
-15V |
5V |
15V |
24V |
| RATED CURRENT |
5.5A |
2.5A |
0.5A |
5.5A |
2.5A |
0.5A |
5.5A |
2A |
0.5A |
4A |
2A |
1A |
| CURRENT RANGE |
0.4 ~ 7A |
0.2 ~ 3.2A |
0 ~ 0.7A |
0.4 ~ 7A |
0.2 ~ 3.2A |
0 ~ 0.7A |
0.4 ~ 7A |
0.2 ~ 2.6A |
0 ~ 0.7A |
0.5 ~ 5A |
0.2 ~ 4A |
0.2 ~ 1.3A |
| RATED POWER |
60W |
63.5W |
65W |
68W |
| OUTPUT POWER (max.) |
Rated output power for convection ;72W with 18 CFM min.Forced air |
| RIPPLE & NOISE (max.) Note.2 |
50mVp-p |
120mVp-p |
50mVp-p |
50mVp-p |
120mVp-p |
100mVp-p |
50mVp-p |
120mVp-p |
100mVp-p |
50mVp-p |
100mVp-p |
200mVp-p |
| VOLTAGE ADJ. RANGE |
CH1:4.75 ~ 5.5V |
| VOLTAGE TOLERANCE Note.3 |
±4.0% |
±7.0% |
±5.0% |
±4.0% |
±7.0% |
±5.0% |
±4.0% |
±7.0% |
±5.0% |
±4.0% |
±6.0% |
±6.0% |
| LINE REGULATION |
±1.0% |
±2.0% |
±1.0% |
±1.0% |
±2.0% |
±1.0% |
±1.0% |
±2.0% |
±1.0% |
±1.0% |
±2.0% |
±3.0% |
| LOAD REGULATION |
±3.0% |
±4.0% |
±1.0% |
±3.0% |
±4.0% |
±1.0% |
±3.0% |
±4.0% |
±1.0% |
±2.0% |
±5.0% |
±5.0% |
| SETUP, RISE, HOLD TIME |
800ms, 20ms,60ms at full load |
| INPUT |
VOLTAGE RANGE |
90 ~ 264VAC 127 ~ 370VDC |
| FREQUENCY RANGE |
47 ~440Hz |
| EFFICIENCY (Typ.) |
76% |
77% |
77% |
77% |
| AC CURRENT |
1.5A/115VAC 0.9A/230VAC |
| INRUSH CURRENT (max.) |
COLD START 20A/115VAC 40A/230VAC |
| LEAKAGE CURRENT |
<0.5mA |
| PROTECTION |
OVERLOAD |
73 ~ 95W rated output power |
| Protection type: Hiccup mode, recovers automatically after fault condition is removed |
| OVER VOLTAGE |
CH1:5.75 ~ 6.75VDC |
| Protection type: Hiccup mode, recovers automatically after fault condition is removed |
| ENVIRONMENT |
WORKING TEMP. |
-10 ~ +60ºC (Refer to output load derating curve) |
| WORKING HUMIDITY |
20 ~ 90% RH non-condensing |
| STORAGE TEMP., HUMIDITY |
-20 ~ +85ºC, 10 ~ 95% RH |
| TEMP. COEFFICIENT |
±0.04%/ºC (0 ~ 50ºC) on +5V output |
| VIBRATION |
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes |
| SAFETY & EMC(Note.4) |
SAFETY STANDARDS |
Design refer to UL60950-1,TUV EN60950-1 |
| WITHSTAND VOLTAGE |
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
| ISOLATION RESISTANCE |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC |
| EMI CONDUCTION & RADIATION |
Compliance to EN55022 (CISPR22) Class B |
| HARMONIC CURRENT |
Compliance to EN61000-3-2,-3 |
| EMS IMMUNITY |
Compliance to EN61000-4-2,3,4,5,6,8,11; Light industry level, criteria A |
| OTHERS |
MTBF |
288.1Khrs min. MIL-HDBK-217F(25ºC) |
| DIMENSION |
127*76*42mm (L*W*H) |
| PACKING |
0.25Kg;54pcs/15.9Kg/1.35CUFT |
| NOTE |
1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature. 2.Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3.Tolerance: includes set up tolerance, line regulation and load regulation. 4.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 5.Mounting holes M1 and M2 should be grounded for EMI purposes. |