50W DC-DC ConverterSD-50 series

50W DC-DC Converter Features:
2:1 wide input range
Protections: Short circuit/Over load/Over voltage
1500VDC I/O isolation
Built-in EMI filter, low ripple noise
100% full load burn-in test
Fixed switching frequency at 83KHz
Low cost
High reliability
SPECIFICATION:
MODEL

SD-50A-05

SD-50B-05

SD-50C-05

SD-50A-12

SD-50B-12

SD-50C-12

SD-50A-24

SD-50B-24

SD-50C-24

OUTPUT DC VOLTAGE 5V 12V 24V
RATED CURRENT 10A 4.2A 2.1A
CURRENT RANGE 0 ~ 10A 0 ~ 4.2A 0 ~ 2.1A
RATED POWER 50W 50.4W 50.4W
RIPPLE & NOISE (max.) Note.2 100mVp-p 120mVp-p 150mVp-p
VOLTAGE ADJ. RANGE 4.5 ~ 5.5VDC 11 ~ 16VDC 23 ~ 30VDC
VOLTAGE TOLERANCE Note.3 ±2.0% ±1.0% ±1.0%
LINE REGULATION ±0.5% ±0.3% ±0.2%
LOAD REGULATION ±0.5% ±0.3% ±0.2%
SETUP, RISE, HOLD TIME 2.5s, 50ms,--- at full load
INPUT VOLTAGE RANGE A:  9.2 ~ 18VDC B:19 ~ 36VDC C:36~72VDC
EFFICIENCY (Typ.) 70% 73% 76% 72% 75% 78% 74% 80% 83%
DC CURRENT 7A/12V 3A/24V 1.5A/48V
PROTECTION OVERLOAD 105 ~ 150% rated output power
Protection type: Fold back current limiting, recovers automatically after fault condition is removed
OVER VOLTAGE 5.75 ~ 6.75V/10% load 16.8 ~ 20V/10% load 31.5 ~ 37.5V/10% load
Protection type: Hiccup mode, recovers automatically after fault condition is removed
ENVIRONMENT WORKING TEMP. -10 ~ +60ºC (Refer to output load derating curve)
WORKING HUMIDITY 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY -20 ~ +85ºC ,10 ~ 95% RH
TEMP. COEFFICIENT ±0.03%/ºC (0 ~ 50ºC)
VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & EMC (Note.4) SAFETY STANDARDS Design refer to LVD
WITHSTAND VOLTAGE I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
EMI CONDUCTION & RADIATION Design refer to EN55022(CISPR22) CLASS B
EMS IMMUNITY Design refer to EN61000-4-2,3,4,6,8;ENV50204,EN55024,light industry level,criteria A
OTHERS MTBF 365.6K hrs min.(SD-50A) 357.5K hrs min.(SD-50B) 368.5K Hrs min.(SD-50C) MIL-HDBK-217F (25ºC)
DIMENSION 159*97*36mm (L*W*H)
PACKING 0.53Kg; 24pcs/12.7Kg/0.75CUFT
NOTE 1.All parameters NOT specially mentioned are measured at normal input, rated load and 25ºC of ambient temperature.
2.Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3.Tolerance: includes set up tolerance, line regulation and load regulation.
4.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.