SPECIFICATION:
| MODEL |
AD-55A |
AD-55B |
| OUTPUT |
DC VOLTAGE |
13.8V |
13.4V |
27.6V |
26.5V |
| RATED CURRENT |
3.5A |
0.23A |
1.8A |
0.16A |
| CURRENT RANGE |
0 ~ 4A |
---------- |
0 ~ 2A |
---------- |
| RATED POWER |
51.38W |
53.92W |
| RIPPLE & NOISE (max.) Note.2 |
50mVp-p |
---------- |
100mVp-p |
---------- |
| VOLTAGE ADJ. RANGE |
CH1:12 ~ 14.5V |
CH1:24 ~ 29V |
| VOLTAGE TOLERANCE Note.3 |
±1.0% |
---------- |
±1.0% |
---------- |
| LINE REGULATION |
±0.5% |
---------- |
±0.5% |
---------- |
| LOAD REGULATION |
±0.5% |
---------- |
±0.5% |
---------- |
| SETUP, RISE, HOLD TIME |
800ms,50ms, 80ms/230VAC 1600ms,50ms, 16ms/115VAC at full load |
| INPUT |
VOLTAGE RANGE |
85 ~ 264VAC 240 ~ 370VDC |
| FREQUENCY RANGE |
47 ~ 63Hz |
| EFFICIENCY (Typ.) |
71% |
74% |
| AC CURRENT |
1.6A/115VAC 1A/230VAC |
| INRUSH CURRENT (max.) |
COLD START 20A/115VAC 40A/230VAC |
| LEAKAGE CURRENT |
<1mA / 240VAC |
| PROTECTION |
OVERLOAD |
105 ~ 150% rated output power. |
| Protection type: Hiccup mode, recovers automatically after fault condition is removed |
| OVER VOLTAGE |
CH1:14.49 ~ 18.63V |
CH1:28.98 ~ 37.26V |
| Protection type: Hiccup mode, recovers automatically after fault condition is removed |
| FUNCTION |
DC ALARM SIGNAL(OPTIONAL) |
AC fail CN1 PIN2 |
| Battery low under charge voltage 82.5% 2% CN1 PIN1 |
| Normal 0.8V max. Abnormal 5V 0.5V |
| ENVIRONMENT |
WORKING TEMP. |
-10 ~ +60ºC (Refer to output load derating curve) |
| WORKING HUMIDITY |
20 ~ 90% RH non-condensing |
| STORAGE TEMP., HUMIDITY |
-20 ~ +85ºC , 10 ~ 95% RH |
| TEMP. COEFFICIENT |
±0.03%/ºC (0 ~ 50ºC) on CH1 output |
| VIBRATION |
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes |
| SAFETY & EMC |
SAFETY STANDARDS |
Design refer to UL60950-1, TUV EN60950-1 |
| WITHSTAND VOLTAGE |
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
| ISOLATION RESISTANCE |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC |
| EMI CONDUCTION & RADIATION |
Compliance to EN55022 (CISPR22) Class B |
| HARMONIC CURRENT |
Compliance to EN61000-3-2,-3 |
| EMS IMMUNITY |
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024,Light industry level, criteria A |
| OTHERS |
MTBF |
304.3K hrs min. MIL-HDBK-217F (25ºC) |
| DIMENSION |
159*97*38mm (L*W*H) |
| PACKING |
0.492Kg; 30pcs/16.37Kg/0.0250CMB |
| NOTE |
1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature. 2.Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3.Tolerance: includes set up tolerance, line regulation and load regulation. |