SPECIFICATION:
| MODEL |
RS-75-3.3 |
RS-75-5 |
RS-75-12 |
RS-75-15 |
RS-75-24 |
RS-75-48 |
| OUTPUT |
DC VOLTAGE |
3.3V |
5V |
12V |
15V |
24V |
48V |
| RATED CURRENT |
15A |
12A |
6A |
5A |
3.2A |
1.6A |
| CURRENT RANGE |
0 ~ 15A |
0 ~ 12A |
0 ~ 6A |
0 ~ 5A |
0 ~3.2A |
0 ~ 1.6A |
| RATED POWER |
49.5W |
60W |
72W |
75W |
76.8W |
76.8W |
| RIPPLE & NOISE (max.) Note.2 |
80mVp-p |
80mVp-p |
120mVp-p |
120mVp-p |
120mVp-p |
200mVp-p |
| VOLTAGE ADJ. RANGE |
3.2 ~ 3.6V |
4.75 ~ 5.5V |
10.8 ~ 13.2V |
13.5 ~ 16.5V |
22 ~ 27.6V |
42 ~ 54V |
| VOLTAGE TOLERANCE Note.3 |
±3.0% |
±2.0% |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
| LINE REGULATION Note.4 |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
| LOAD REGULATION Note.5 |
±2.0% |
±1.0% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
| SETUP, RISE, HOLD TIME |
500ms, 30ms, 60ms/230VAC, 500ms, 30ms, 14ms/115VACat full load |
| INPUT |
VOLTAGE RANGE |
88 ~ 264VAC 125 ~ 373VDC |
| FREQUENCY RANGE |
47 ~ 63Hz |
| EFFICIENCY (Typ.) |
71% |
76% |
81% |
82% |
85% |
86% |
| AC CURRENT(Typ.) |
2A/115VAC 1.2A/230VAC |
| INRUSH CURRENT (Typ.) |
COLD START 40A/230VAC |
| LEAKAGE CURRENT |
<2mA / 240VAC |
| PROTECTION |
OVERLOAD |
110 ~ 150% rated output power |
| Protection type : Hiccup mode, recovers automatically after fault condition is removed |
| OVER VOLTAGE |
3.8 ~ 4.45V |
5.75 ~ 6.75V |
13.8 ~ 16.2V |
17.25 ~ 20.25V |
27.6 ~ 32.4V |
55.2 ~ 64.8V |
| Protection type : Hiccup mode, recovers automatically after fault condition is removed |
| ENVIRONMENT |
WORKING TEMP. |
-25 ~ +70ºC (Refer to output load derating curve) |
| WORKING HUMIDITY |
20 ~ 90% RH non-condensing |
| STORAGE TEMP., HUMIDITY |
-40 ~ +85ºC, 10 ~ 95% RH |
| TEMP. COEFFICIENT |
±0.03%/ºC (0 ~ 50ºC) |
| VIBRATION |
10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes |
| SAFETY & EMC(Note4) |
SAFETY STANDARDS |
Design refer to UL60950-1,TUV EN60950-1 |
| WITHSTAND VOLTAGE |
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
| ISOLATION RESISTANCE |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC |
| EMI CONDUCTION & RADIATION |
Compliance to EN55022(CISPR22) Class B |
| HARMONIC CURRENT |
Compliance to EN61000-3-2,-3 |
| EMS IMMUNITY |
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61000-6-2 (EN50082-2) heavy industry level, criteria A |
| OTHERS |
MTBF |
265Khrs min. MIL-HDBK-217F (25ºC) |
| DIMENSION |
129*97*38mm (L*W*H) |
| PACKING |
0.41Kg; 30pcs/13.3Kg/0.86CUFT |
| NOTE |
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Line regulation is measured from low line to high line at rated load. 5. Load regulation is measured from 0% to 100% rated load. 6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. |
|